This cable is used to connect the Phoenix Inverter models (discontinued) 12/180, 24/180, 12/350, or 24/350 to a VE.Bus BMS or a BlueSolar MPPT Charger featuring a load output:
- For VE.Bus BMS: The inverter will be switched off when the batteries are empty.
- For BlueSolar MPPT Charger: The inverter must be connected to the battery, and this cable is used to switch the inverter on and off with the load output.
The load output of an MPPT 75/15 or MPPT 100/15 can control an inverter. Some inverters switch on when the remote control input is pulled high, while others must be pulled down. The Victron Phoenix inverter models 12/180, 24/180, 12/350, and 24/350 require a pull-down to switch on, interfacing with the load output of the MPPT 75/15 or MPPT 100/15 using this inverting remote on-off cable.
All Phoenix inverters rated at 3kVA and above, along with all MultiPlus and Quattro models, also require active pull-down to switch on, making this cable essential for connecting between the remote on-off terminal and a source signal that activates the inverter.